Narda nada fieldman, germany, has a frequency range of 0 hz-90 ghz for non-ionising electromagnetic radiation measurements, which accurately measure the strength of high frequency and low frequency signal fields。
Introduction to the product of the nardanada field man complex:
Narda field man, which is used for non-ionizing electromagnetic radiation measurements, can accurately measure the strength of high and low frequency signal fields. A digital probe measuring the strength of an electric field or magnetic field covers medical, static and low frequency field measurements in industrial applications, and applied measurements of mobile radio frequencies and millimetre waves. The digital probe includes a flat response to the probe and a power probe based on the full standard of the body*. Low-frequency probes have a fft analysis function that allows spectrum measurements and time-area analysis, with a frequency of up to 400 khz, with digital interfaces that allow reliable and accurate transmission of measured data to the host, which does not require calibration。
Fieldman provides users with two versions, one for wireless communication and voice recording, and the other for wireless communication without microphones。
Characteristics of the products of the nardanada field field tester, germany:
Use same-sex probes, frequency range 0 hz(dc)-90ghz
5-inch colored clean screen, 1280X 720 resolution, application of outdoor light environment
Both broadband and selected frequency probes use digital probe interfaces – hosts are not required clear
A powerful frequency and time-area analysis function for low frequencies up to 400 khz, which supports the measurement of power peaks
Optional wifi/bluetooth interface to support mobile app remote operation
Internal gps receiver and ranger (optional) i'm not sure
Rapid data transmission: fibre-optic interface, gigabytes, usb-c
Nardanada field man, germany, application of the field tester:
Field man can accurately measure the strength of the electromagnetic radiation field, especially in the working environment where there may be a strong electric field or magnetic field radiation, thereby ensuring the integrity of the body. An essential task of electromagnetic radiometry is to determine whether * the requirements of the whole statute are met, e. G. Fcc, ieee, icnirp or emf directive 2013/35/eu. Typical measurement scenarios include:
Wireless telecommunications base station (e. G. Iec/en 62232)
Broadcasting system (e. G. Iec 62577)
Radar and satellite communications systems
Sensor heating and melting (e. G. En 50519)
Home appliances (e. G. Iec / en 62233)
Welding equipment (e. G. Iec / en 628222)
Railway system (e. G. En 50500)
Automobile systems (e. G. Iec 62764)
Energy supply systems (e. G. Iec / en 62110)
Electronic medical equipment (e. G. Iec / en 6001)
Emc test tem room and shield room
Technical parameters for the nardanada field field tester, germany:
1. Generic specifications:
* calibration cycle: mainframe does not need calibration, only probe calibration
Power supply (internal): lithium ion charged batteries, replacement
Power supply (external): usb-c pd (* big 12 v / 3a, compatible bc1. 2 and qc 3. 0)
Operating time (pronounced): 16 hours (using broadband probes and analysers)
Recharge time (specify): 4 hours (2. 5 hours charged to 80%)
Radio-frequency resistance to disturbance: 200 v/m (100 khz-60 ghz); less than the range allowed by the probe
Static magnetic field environment use: ≤30 mt (avoiding field too strong)
Dimensions (h x w x d): 51 mm x 93 mm x 312 mm, excluding probes
Weight: 695 g (excluding probes)
Origin: germany
List of configurations of the nardanada field man complexator in germany:
Instrument kits
"fieldman host 1 -- does not include probes –
Including:
Fieldman host 2460/01
Fieldman hard protection box, with 5 probes
Charger usb-c pd, au/eu/uk/us plugin
Usb line, 2x usb-c(m) interface, 3a, 2m
A belt, 1 m
Spectrum tags
Quick manual
* full description
Disk: manuals and documents
Narda-tsx software (free download)
"fildman hosts" - does not contain probes –
Including:
Fieldman host 2460/02 (wireless communications not supported)
Fieldman hard protection box, with 5 probes
Charger usb-c pd, au/eu/uk/us plugin
Usb line, 2x usb-c(m) interface, 3a, 2m
A belt, 1 m
Spectrum tags
Quick manual
* full description
Disk: manuals and documents
Narda-tsx software (free download)
2. Digital broadband probes
Magnetic field probe hfc-3061 300 khz-30 mhz
Magnetic field probe hfd-0191, 27 mhz-1 ghz
Efd-0391, 100 khz-3 ghz
Efd-0392, high power, 100 khz-3 ghz
Ed-0691 100 khz-6 ghz
Edd-0692 600 mhz-6 ghz
Efd-1891, 2 mhz-18 ghz
Efd-1891, rapid response, 2 mhz-18 ghz
Ed-4091, 3 mhz-40 ghz
Efd-5091, 300 mhz-50 ghz, thermoelectric doll
Effd-6091 100 mhz-60 ghz
Effd-9091 100 mhz-90 ghz
Power field detective ead-5091, fcc 1997 standard, 300 khz-50 ghz
Ieee 2019 standard, 3 mhz-50 ghz
Power field detective ecd-5091, sc 6 2015 standard, 300 khz-50 ghz
Icnirp 2020 occupational standard, 1 mhz – 50 ghz (compatible with icnirp 1998 30 mhz above)
3. Digital selected frequency probes
Select frequency detector bfd-400-1, low frequency magnetic field, 100 cm2, 1 hz/400 khz
Select frequency detector bfd-400-3, low frequency magnetic field, 3 cm 2, 1 hz/400 khz