The nf-5035 handheld mma field power tester in arnoni, germany, is perfectly applied to the electromagnetic compatibility/electromagnetic disruption pre-accreditation test, with a frequency of 30 mhz. Multiple options are available to enhance the spectrum analyser function。
Nf-5035 handheld mma field power tester application, arnoni, germany:
Geomagnetic field measurements, as well as geological exploration, very low frequency vibration tests, electromagnetic radioactivity selected frequency analysis, rfid testing and development of electromagnetic compatibility tests
Application band: static magnetic field very low frequency, low frequency (3hz-300khz) worker frequency (50hz/60hz) medium frequency (300khz-3mhz) high frequency (3mhz-30 mhz)
Vlf vibration test and analysis
Frequency and hf electromagnetic radiation analysis for transmission and distribution systems
Electromagnetic compatibility
Scientific research, product development
Higher education
Environmental electromagnetic radiation monitoring
Safety monitoring of electromagnetic fields in the workplace
Electromagnetic security detection of defence electronics
Monitoring of the electromagnetic environment of aerospace equipment
Railway towed grid
Power lines and cables
Transformer
Power systems and harmonization
Energy-efficient light bulbs
Switch the power
Tft, lcd lcd crystal monitor and television
Dsl
Adsl
Vdsl
13. 56 mhzrfid
Electromagnetic detection of household, office, industrial appliances with various work frequencies up to 30 mhz
Partial application of standards and measurement methods:
Gb 8702-2014 provisions for protection against electromagnetic radiation
Gjb 5313-200 limitation values and measurement methods for electromagnetic radiation exposure
Hj-t 10. 2-1996 guidelines for the management of radiation environmental protection — instrument and methods for monitoring emps
Hj/t24-1998 technology for assessment of the environmental effects of electromagnetic radiations of superhigh voltage transfer engineering
Gbz2. 2-2007 limitation of occupational exposure to harmful factors in the workplace
Gbz/t189. 2-2007 part 2: 100 khz ~ 30 mhz high-frequency electromagnetic field for physical measurements of industrial sites
Gbz/t189. 3-2007 part 3: 50hz industrial frequency field
Specifications
•
Name:
Hand-held electromagnetic radiation test spectrum analyser
•
Type:
Spectran nf5035
•
Frequency range:
1hz to 1mhz (option 010 extended to 30 mhz)
•
Magnetic field range (tesla):
1 pt to 500 mt (50hz)
•
Magnetic range (gauss):
10ng to 5g (50hz) (option 009)
•
Field range:
0. 1v/m to 5kv/m (50hz)
•
Simulate input
200nv to 200mv (typical)
•
Minimum sampling time:
10ms
•
Resolution bandwidth (rbw):
0. 3hz to 1 mhz (1-3-10 step)
•
Available units:
V, v/m, t, g, a/m
•
Receptor:
Rms, min/max
•
Relief:
Am, fm
•
Input (input):
50 om sma radio frequency input
•
Audio:
Internal speaker (sound control and standard 2. 5 mm plug)
•
Precision:
3% (typical)
•
Data recorder:
64k (option 001 extended to 1mb)
•
Data interface:
Usb2. 0/1. 1
•
Dimensions (l/w/d):
250X86x27 mm
•
Heavy:
430g
•
Quality assurance:
2 years
Measuring magnetic sensitivity (measured in teslat)
Measurement range: 1nt; -2mt(typ.) (tesla) (through built-in probes) with pbs1 detector to expand the test range
Measurement range extension: 1pt-2mt (typ.) (tesla) (typical test range) when using option 005 (digital subfrequency frequency frequency frequency frequency frequency filter)
Measuring magnetic sensitivity (measurement unit: goss g)
Measurement range extension: 10 μg-20g(typ.) (gauss) (typical test range) when using option 006 (3d static magnetic field sensor)
Measurement range extension: 10ng-20g(typ.) (gauss) (typical test range)
Measurement of field strength (measured in v/m or kv/m)
Measurement range: 0. 1v/m - 20kv/m (through internal probes)
Sma interface simulation input voltage: 2 μv-200mv (typical test range) simulate input range extension: 200nv-200mv (typical test range) when using option 005 (digital variable frequency frequency filter)
Resolution bandwidth rbw
Range: 0. 3hz 1 mhz (1-3-10 step) (step 1-3-10)
Units: v/m, a/m, t, g
Receptor: equivalent root, peak
Decomposition: am fm
Enter port: high resistance to 50 omsma port input
Speech port: inline speaker, volume control, 2. 5 mm voice plugin
Measurement precision, typical value: 3%
Data communication port: usb 2. 0/1. 1
Dimensions (long/wide/high): 250X86x27 mm
Weight: 420 g