The rit fim film analysis software, the rit film film dosage analysis software, is an rit film dosing software product with patient quality assurance and basic machine and multileaf straighter quality assurance functions。
The rit film software package provides a full set of film dosing procedures, including patient quality assurance and basic machine quality assurance. With rit's automated batch analysis function, runqueuea, you can easily simplify the patient quality assurance process and export any analytical program to the PDF report。Patient quality assurance
The rit film patient quality assurance (imrt) program aims at comparing patient body-modulation programmes in the user treatment plan system with the quality-assurance images of films exposed to the module. The software allows easy comparison between plans and films, plans and programmes, and films and films. Imrt and vmat for patent program calibration for r it analysis
- You can quickly compare any dose maps with your epid, film and cr images. (proposals: ep 1683546, ca 2567197, jp 4366362, jp 4838161, us 70244026, us 7233688, us 76398551 and us 7680310)
- Gamma function
- Distance to agreement (dta)
- Introduction
- Van dyke's analysis
- Subtract
- Comprehensive analysis
- Equal dose curve
- Add
- Physic and heart measurements
- Imrt automatically fine-tuned
- Autoregistration
- Scale adopted
- Patient quality assurance image alignment: fully automated control point positioning is implemented in both traditional imrt and runqueuea imrt. Template-based alignment can also be implemented。

2d detector array analysis
Two-dimensional array import: supports the import of ionizing chamber array data from iba, ptw and mapcheck. The imrt analysis program has been updated to process the thin data. The result can be saved as the rit array case file. Mapcheck is the registered owner of sun nuclear corp. Indicators
Automatic image fill for human model quality assurance
Use this feature to automatically correct and fill any holes or gaps in the image file. Patient quality assurance using human models for calibrated and uncorrected images。
Calibration
- Rit patent mlc calibration technology (patent number: ep 1318857, ca 2418232, jp 3817176, us 6675116, us 6934653 and us 7013228)
- Vertical dose calibration
- Parallel dose calibration
- Photodensity (od) calibration
- Space calibration of 2d scanners for vidar board scanners
- PDF table editor
- Consolidation of calibration documents
Machine quality assurance and beam measurements
- Full automatic astrometric analysis: the rit enhanced star-ray beam detection program has a fully automated interface with a powerful, high-precision ai algorithm. Polarity, roi, the number of irradiated strips and the centre of irradiated strips are automatically extracted from images and applied for analysis。
- Radiation/light field matches
- Radio-light field co-operation does not require calibration documents to analyse radiation/lightfield epid images. You can also customize field exposure (not only 5 cm, 10 cm, 15 cm and 20 cm) and use a bb bullet or needle for central positioning or l-rad body modelling。
- Depth dose, cross-cutting and positive distribution
- Electronic energy (tt-25)
- Fast flat and symmetrical
- Equivalent line contour
- Stereodirective calibration (2d winston-lutz) tests
- Stereo-direction cone cone contour
- Alignment
- Import tomotherapy calibration files
Mlc qa
- Bayouth mlc analysis analyses mlcs that need to leave leaves between river banks。
- General fence test (in memory of sloane-cateline hospital fence style)
- Mlc transfer analysis (recommended tg50)
- Tt50 stake fence
- Valiant dmlc test model analysis
- Test 1: array
- Test 2: synchronize division stripes
- Test 3: non-synchronous stripes
- Test 4: x wedge single-banded and synthesized images
- Test 5: y wedged single and synthetic images
- Test 6: pyramid single and synthetic images
- Test 7: complex a
- Test 8: complex b
- Test 9: continuous stripes