Synopsis of rigel patsim200 patients:
An affordable, easy-to-use model patient
Program your patsim200 to remember your most common simulation
Immediate low-cost alternatives for modelling old patients
Simple, fast navigation uses a dedicated homepage button and call key
Light and compact devices with rechargeable lithium ion batteries
Provision of 5-year warranty and 90-day return policy
Meet the criteria:
Jjg 760-2003 cardiac monitor inspection protocol
Jjf 1470-2014 cardiac monitor inspection protocol
Rigel patsim200 patient simulator
Reference button
The new patsim200 from rigel aims to make it easier for each of your patients to simulate。
Unlike other patient simulator models, patsim200 uses home and recall functions to easily move between tests and store the most commonly used sequences, without needing to click and scroll tree structures to perform each test。
Rigel patsim200 patient emulator simulation
12 leads to a simulation of the nsr electrocardiogram
More than 40 optional cardiac disorders
Performance wave
Respiratory simulation of lead i and ii
Generic temperature simulation
Double channel ibp simulation
Fetal simulation
One of the most unique functions of the rigel patsim 200 patient simulator is to preserve five of the most commonly used simulations, which can be called by pressing three buttons。
The device itself is structurally compact and light, and full colour screens are easy to change the high contrast low brightness light, meaning that adaptation to use the device in low lighting environments is simple. In addition to these excellent functions, we also ensure that patsim200 has a universal ecg screw and a mini din connection, so the cost of converting your patient simulator to patsim200 will not be out of control -- our department will use most of the legacy ibp and temperature cables you already have。
Rigel patsim200 patient simulator specifications
| Simulation type | |
|---|---|
| All 12 lead esgs, each signal leads independently | |
| Lead me | 70% |
| Lead ii | 100% |
| Lead iii | 30% |
| Leadership v1 | 24% |
| Lead v2 | 48 per cent |
| Lead v3 | 100% |
| Lead v4 | 120% |
| Lead v5 | 112% |
| Lead v6 | 80% |
| Ekg | |
|---|---|
| It's normal | |
| Heart rate | 30, 40, 50, 60, 70, 80, 90, 100, 120, 140, 160, 180, 200, 220, 240, 260, 280, 300 bpm |
| Rate accuracy | ±1 bpm or 1% |
| Range (conductor ii) | 0. 05 to 0. 45 mv (0. 05 mv step) 0. 5 to 5. 5 mv (0. 5 mv step) |
| Range precision | ± 2% |
| St division of markets | 18 optional values, 8 up and 8 down -0. 8 to + 0. 8 mv with 0. 1 mv step length and + 0. 05 mv and -0. 05 mv guide ii |
| Neonatal mode | Ekg r wave width reduced to 40 ms |
| Ekg performance test | |
|---|---|
| Fang bo | 2hz, 0. 125hz |
| Delta wave | 2hz |
| Pulse | 60bpm or 240bpm |
| Sinewave | 0. 05, 0. 5, 1, 10, 25, 30, 40, 50, 60 and 100 hz |
| Performance range | 0. 5 to 5. 0 mv, step 0. 5 mv |
| A pacemaker | |
|---|---|
| Simulate rhythm | Step 75 bpm Demand is high on heart beats Demand sometimes goes too fast Av order Non-capable No function |
| Pulse range | 1. 0, 2. 0, 5. 0, 10. 0 mv |
| Precision | ± 10% |
| Width | 0. 1. 02, 0. 5, 1. 0, 2. 0ms |
| Precision | ± 5% |
| R-wave detector test | 30, 60, 80, 120, 200, 250 bpm |
| Haft triangle width | Eight, 10, 12, 20, 40, 60, 80, 100, 120, 140, 160, 180, 200 |
| Performance range | 0. 5 to 5. 0 mv, step 0. 5 mv |
| Heart failure | |
|---|---|
| Heart | Cardiac arrest Second San Cardiac fibre (bold) Cardiac fibrosis (precision) The heart of the room is moving too fast |
| The room's moving too fast | Room tremors (bold) Diarrhoea (precision) My heart is pounding The room's moving too fast Missing beat Lymph nodes Synoplasmic hysteria The heart rate is not the same The heart of the room is moving too fast |
| Cartient | Level 1 av block Left blank Right side branch - mobitz i Secondary av block - mobitz ii Level 3 av block |
| It's too early | A premature contraction of the heart Early contraction A premature contraction of the left heart - early - r on t Premature birth Early contraction of the right heart Right-heart constriction - r t t Room premature - 6 / min Premature heart contraction - 12 / min Room premature - 24 / min Room-based early combat - frequent multiple |
| Fetal simulation | |
|---|---|
| Mother's heart rate | 80 bpm (fixed) |
| Heart rate (optional) | 60, 90, 120, 140, 150, 210 and 240 bpm Iup 140 bpm starts with pressure |
| Inner pressure waveform | Early deceleration, later deceleration and even acceleration |
| Simulation period | Manual, or 2, 3 or 5 minutes |
| Blood pressure | |
|---|---|
| Channel | 2 channels |
| Quiet pressure | -10, 5, 0, 20, 40, 50, 60, 80, 100, 150, 160, 200, 240, 320, 400 mmhg |
| Dynamic simulation | Arterial [art] 120/80 Artery [ra] 120/80 Left heart [lv] 120/00 Right heart [rv] 25/00 Right heart room (centre vein) [cvp] 15/10 Lung artery [pa] 25 / 10 Pulmonary artery weeds [paw] 10/2 [la] 14/4 |
| Automatic sequence (channel 1 only) | |
| Cycle simulates 15 seconds duration: | Arterial [art] 120/80 Artery [ra] 120/80 Left heart [lv] 120/00 Right heart [rv] 25/00 Pulmonary artery weeds [paw] 10/2 Lung artery [pa] 25/10 Right heart room (centre vein) [cvp] 15/10 |
| Precision | ±1 mmhg |
| Incentive voltage | 2 to 16v |
| Interdiction | 350 times |
| Simulate sensitivity | 5 μv/v / mmhg or 40 μv / v / mmhg (user options) |
| Connector | Mini-din style |
| Temperature | |
|---|---|
| Simulation | Ysi 400 / 700a / 700b static |
| Temperature units | °c or °f, optional |
| Scope | 0. 0, 24. 0, 37. 0 and 40. 0°c 32. 2, 75. 2, 98. 6, 104. 0°f |
| Precision | ± 0. 1°c/°f |
| Connector | Mini-din style |
| Breathe | |
|---|---|
| Price | Optional value 0, 5, 10, 15, 30, 40, 60, 80, 120, 180 brpm |
| Lead selection | Leadership i and ii, user options |
| Base resistance | 500, 1000, 1500 and 2000 times |
| Precision | ± 5% |
| Change of resistance | 0. 2, 0. 5, 1. 0, 3. 0 times |
| Precision | ± 10% |
| Respiration pause simulation | Manual switches/off |
General specifications
| Main power source/cell information | 3. 7v 3900m ah 14. 4wh lithium ion batteries 5v 1a usb mini b power 100-240v〜50 / 60hz max. 0. 18a |
| Charge time (new batteries) | 3-4 hours |
| Battery lifetime | 6 hours, about 4 hours |
| Weight | 0. 70 kg/1. 5 pounds |
| Outer size | 180 x 150 x 55mm, 7. 1 x 5. 9 x 2. 2 " |
| Environmental indicators | |
|---|---|
| Run conditions | 10 - 40°c (50 - 104°f) 0 - 90% rh - nc |
| Storage environment | 15 - 60°c (5 - 140°f) 0 - 90% rh - nc |
| Environmental protection | Ip40 |
| Services and warranties |
|---|
| Each patsim unit has a five-year warranty and 90-day refund guarantee for free upgrade |
| Spare parts number | |
|---|---|
| Patsim200 | 404a920 |