Accupulse xl non-creative pressure simulator summary:
• optional caltablestm: accupulse xl's new caltabletm technology provides the first nibp simulator to accurately test nibp monitors. Secure caltablestm is the answer to the industry question using the nibp simulator to test the nibp monitor accurately and consistently. Select the right caltabletm on the accupulse xl, and then use the preset for the precise nibp test。
• use the appropriate caltablestm means that the nibp monitor readings can be expected to match the accupulse xl bp settings
• caltablestm, which can be used in a variety of popular nibp monitors, has 45 caltables that can be stored and updated for on-site upgrading。
• accupulse xl simulates the biologically correct waveform, properly tested and validated methods for nibp monitors。
• the accupulse xl simulation engine uses very low friction design components, leaving little wear。
7 adult presets cover the full range from hypo to hyper。
• 6 neonatal presets cover the entire range from 35/15 to 1,50/120
• automatic sorting in preset and optional user definition modes。
• if necessary, presets can be replaced for testing between presets。
• users can change pulse rates。
• patented nibp simulation technology - american patent 5,027,641
• accupulse xl always uses nibp monitor cuff belts for testing; failure to check cuff belts may be the main source of the problem。
• accupulse xl provides high-precision digital pressureometers。
• the weight of accupulse xl is half of most other fully functional nibp testers and includes an built-in battery。
• accupulse xl has graphic displays. This allows it to provide an inflatable/influencing cuff belt that can be used to diagnose abnormal nibp monitor behaviour。
• integrated cuffband support for adults and neonatal attachments。
• internal pumps
• leak test
• pressure, “eject” valve tests
• internal lithium batteries with smart chargers
• comprehensive remote control orders library
• an optional user definition model allows for independent compression and the setting and adjustment of stretching settings and advanced test requirements for specific equipment。
• optional motion simulation software modules。
• an optional simulator module for heart disorders。
Accupulse xl nibp simulator provides accurate blood verification test pressure monitors. Accupulse xl is the first precise nibp simulator that uses the biologically correct waveform used to test blood pressure monitors。
The accupulse xl nibp simulator, accupulse xl non-fibrous blood pressure simulator, includes the following test mode:
Blood pressure test model: pre-set and biologically correct adults and newborns are selected to provide an accurate test blood pressure monitor. Accupulse xl also provides the widest range of adult and any nibp simulator's neonatal simulation range。
Leaking test mode with high-precision digital pressureometers: automatic testing of leakage rates for sphygmomanometers, cuffbands and hose components. Users can configure and save 3 test combinations for use under different requirements. This model also provides high-precision digital pressure meters。
Leaking test mode with high-precision digital pressureometers: automatic testing of leakage rates for sphygmomanometers, cuffbands and hose components. Users can configure and save 3 test combinations for use under different requirements. This model also provides high-precision digital pressure meters。
Overpressure test mode: self-test the depressure valve of the operating pressure monitor for blood and record the release of the fixed point pressure from the safety valve。
Instrument mode: except for 0. 1 mmhg resolution pressureometers, this mode provides a pool pressure from automatic inflating to preset values or defined by the user to verify static calibration throughout the range. If you want, the user can change the measurement value of this mode。
Note: the device may be zero at one minute intervals in order to eliminate any drift. There'll be a slight whirlwind. This will occur automatically and only when the system does not expand or test proactively。
The principle of oscillating blood pressure
Unlike nibp, which uses a hearing device, the mic, oscillation method uses pulse or oscillating cuff pressure to determine the blood pressure of the patient. The cuffs are inflated above the constriction pressure, followed by linear or gradual contraction. Pulse bands are small when cuff pressure is high; however, as cuff pressure lowers, pulses increase and then begin to decrease. During the venting period, the cuff-band oscillation was measured and stored along with the cuff-band pressure. An oscillation range based on the cuffband is then drawn to create the pressure of the oscillation convex. The oscillation then uses an envelope to determine the patient's blood pressure. It's generally known that the mean arterial pressure (map) is present at peaks, with the highest cufflink oscillation. Unfortunately, there is no universally accepted formula to determine the constriction and stress. The nibp monitor manufacturer has developed unique proprietary algorithms to estimate constriction and constriction from oscillation condensation。
Caltablestm:
Accupulse xl's new caltabletm technology makes it the first nibp simulator to resolve algorithmic changes between different nibp monitors. The optional caltablestm is the use of nibp simulators to answer questions about accurate and consistent testing of nibp monitors. Select the right caltabletmxl on accupulse, and then use the preset of the definition for an accurate nibp monitor test. Accupulse xl can store up to 45 defined caltablestms for accurate testing of nibp monitors. These caltablestms have been approved for testing and development through direct cooperation with nibp monitoring manufacturers to ensure that the tests are accurate. The new caltablestm has been published on a continuous basis
The inclusion of a generic preset does not represent an algorithm for a particular manufacturer, but rather an intermediate approximation, which will provide replicable results. It could be user-specific and appropriate at the appropriate time. The optional user definition software module expands this feature and provides up to 45 custom predefined storage spaces for special applications and advanced users。
Instrument mode: except for 0. 1 mmhg resolution pressureometers, this mode provides a pool pressure from automatic inflating to preset values or defined by the user to verify static calibration throughout the range. If you want, the user can change the measurement value of this mode。
Note: the device may be zero at one minute intervals in order to eliminate any drift. There'll be a slight whirlwind. This will occur automatically and only when the system does not expand or test proactively。
The principle of oscillating blood pressure
Unlike nibp, which uses a hearing device, the mic, oscillation method uses pulse or oscillating cuff pressure to determine the blood pressure of the patient. The cuffs are inflated above the constriction pressure, followed by linear or gradual contraction. Pulse bands are small when cuff pressure is high; however, as cuff pressure lowers, pulses increase and then begin to decrease. During the venting period, the cuff-band oscillation was measured and stored along with the cuff-band pressure. An oscillation range based on the cuffband is then drawn to create the pressure of the oscillation convex. The oscillation then uses an envelope to determine the patient's blood pressure. It's generally known that the mean arterial pressure (map) is present at peaks, with the highest cufflink oscillation. Unfortunately, there is no universally accepted formula to determine the constriction and stress. The nibp monitor manufacturer has developed unique proprietary algorithms to estimate constriction and constriction from oscillation condensation。
Caltablestm:
Accupulse xl's new caltabletm technology makes it the first nibp simulator to resolve algorithmic changes between different nibp monitors. The optional caltablestm is the use of nibp simulators to answer questions about accurate and consistent testing of nibp monitors. Select the right caltabletmxl on accupulse, and then use the preset of the definition for an accurate nibp monitor test. Accupulse xl can store up to 45 defined caltablestms for accurate testing of nibp monitors. These caltablestms have been approved for testing and development through direct cooperation with nibp monitoring manufacturers to ensure that the tests are accurate. The new caltablestm has been published on a continuous basis
The inclusion of a generic preset does not represent an algorithm for a particular manufacturer, but rather an intermediate approximation, which will provide replicable results. It could be user-specific and appropriate at the appropriate time. The optional user definition software module expands this feature and provides up to 45 custom predefined storage spaces for special applications and advanced users。
Accupulse xl nibp simulator, accupulse xl non-creative pressure simulator technical specification:
Accupulse xl nibp caltablestm
Datascope accutorr plus
Ge medical dash 4000
Ge medical dinamap pro
Philip medical m3
Welch-allyn propaq encore
Philip medical services vs1
Colin medical
Criticism
Medical
Sunde
More. Please contact the factory to obtain the availability of other calibration forms。
B. P. Pre-introduced/stuff pressure (map):
Adult:
240/190
200/150
150/100
120/80
100/70
80/50
60/30
Newborn:
1150/120
120/90
100/70
80/50
35/15
60/30
The exact relief, constriction and map values are specific caltablestm. The bp preset above is used from generic caltabletm。
Accuracy: ±0. 5 mmhg
Range of oscillatory pulses: 0-150 per cent of nominal value
Pulse range resolution: 1%
Heart rate pulse range: 15-330 bpm
Pulse accuracy: ± 0. 5 bpm, 15-300 bpm, ± 1 bpm 301-330 bpm
Display/measure parameters:
Dynamic nibp cuff pressure waveform
Digital pressureometer range: 0. 0 to 400. 0 mmhg
Accuracy: 0 – 400 mmhg ± 0. 5 mmhg
Resolution: ± 0. 1 mmhg
Datascope accutorr plus
Ge medical dash 4000
Ge medical dinamap pro
Philip medical m3
Welch-allyn propaq encore
Philip medical services vs1
Colin medical
Criticism
Medical
Sunde
More. Please contact the factory to obtain the availability of other calibration forms。
B. P. Pre-introduced/stuff pressure (map):
Adult:
240/190
200/150
150/100
120/80
100/70
80/50
60/30
Newborn:
1150/120
120/90
100/70
80/50
35/15
60/30
The exact relief, constriction and map values are specific caltablestm. The bp preset above is used from generic caltabletm。
Accuracy: ±0. 5 mmhg
Range of oscillatory pulses: 0-150 per cent of nominal value
Pulse range resolution: 1%
Heart rate pulse range: 15-330 bpm
Pulse accuracy: ± 0. 5 bpm, 15-300 bpm, ± 1 bpm 301-330 bpm
Display/measure parameters:
Dynamic nibp cuff pressure waveform
Digital pressureometer range: 0. 0 to 400. 0 mmhg
Accuracy: 0 – 400 mmhg ± 0. 5 mmhg
Resolution: ± 0. 1 mmhg
Leak test
Auto-inflatestart pressure: 3 user presets can be set and saved
Each transferable: 50-300 mmhg
Time used: can set and save 3 user presets for 20-120 seconds
High-resolution pressurers: 0. 0 to 400. 0 mmhg
Overpressure
Automatically test the monitor safety valve operation
Popup pressure range: 10 to 400 mmhg
Interim pressure: 0 to 400 mmhg
Auto sort
Users can use automatic sequence testing for the performance of the nibp monitor accupulse xl nibp with a specified series. A special user sequence and optional user definition mode, accupulse xl, was added to provide portable and user-friendly use of adult sleeves. It also provides a neonatal axle
• neonatal (1. 25 inch diameter, 2. 25 inches wide)
Switch to the hose
Adaptor hoses insert between nibp equipment, cuffbands and analysers. These adapters are compatible with the nibp monitor。
• public/murour
• male/female crippard (gemedical, draeger/siemens)
• colder/cpc (gemedical, protocol system)
• obac rapid release device (philip medical)
• universal 5/32 "id hoses
Self-checking accessories
• pressure ball components (three cuff adapters inserted)
• self-system leakage test hoses (diplomatic congestion)
Communications port
1 usb mini port
1 db9 rs232 port
Presentation
Led backlight
Resolution: 320 x 240
Power: 100-240 vac, 50 w, 50-60 hz
Desktop switcher output: 24vdc@2. 1a,6-foot cable
Security agency certification: ul, ce, tuv
Internal batteries: lithium ions (lion)
Power 16. 5v capacity: 2. 5a-hr, usually 150 nibp simulation
Charge time: 3. 5 hours
6 pounds。
8 "wide x 5 " high x 12 " long
Standard accessories
• external power supply and power lines
• new-born cuffbands
• adult sleeves (inlined)
• five adaptor hoses
• operational manual on cd
• internal pumps
• internal batteries
Optional accessories
• carrying luggage
• caltables software module
• user-defined software modules
• sport software modules
• cardiopathic software module