Description of function of ecs7 electrothermal blanket control panel
Terms of reference:
Work voltage ac 190v-250v and load power maximum 60w。
Ii. Presentation pattern:
A red digital tube displays a power level of 1-7 and an automatic (h-l) conversion barrier。
2 green digital tube shows power (1-9) hourly timing。
Power control:
1 power reconciliation: power reconciliation is performed in the following manner: set power segment 7 with a 10-second cycle。
The first tranche (30 per cent)-2 (40 per cent)-3 (50 per cent)-4 (60 per cent)-5 (70 per cent)-6 (80 per cent)-7 (90 per cent) sets the temperature slot。
Automatic power conversion:
Sets automatic slots, which are automatically converted from 100% power output to 20% power output after one hour, and the red digital tube corresponds to the "h"-1 hour "l" display。
V. Timing:
In working conditions, time keys can be set for 1-9 hours (nine tranches). The green digital tube shows a time-out at the actual time remaining until the end of the time state, showing "00"
Vi. Stand-by status
Start and time end: power and time display "00"
You can set the temperature to build an automatic key
Stand-by status. Time keys are not working
Vii. Reconciliation settings:
1 the initial click on the temperature key once, the power is shown "7 " , the time default is shown "9 " ; the again click on the temperature key, the power is shown in the "1 " -7 " cycle。
Initial button clicks, power shown " h " and time defaults shown " 9. "。
Three
The ratio shows any state of " 1 " - " 7 " , clicks the automatic key, and the power displays no change in the time remaining for h。
4. In the case of power displays "h" and "l" states, the temperature key power is shown as "7" and the time remaining remains constant。
5. In power displays "h" and "l" states, clicking on automatic keys is not working。
Viii. Malfunction protection:
Open road protection: load (z1-z2) and detection line (s1-s2) open, power cut within 3 seconds, displaying "p0"
Short-circuit protection: (z1-z2) and (s1-s2) any of the resistance values between (300 k (1)(10%) and 0 are cut off within 3 seconds to display "e0"。
Shenzhen city liqing microelectronics ltd., which focuses on the development of electro-thermal blankets, electro-thermal blanket ic chip, electro-thermal blanket temperature control pcba programme, electro-thermal blanket timing ic chip, temperature control mono-machine programme development, smart electro-thermal blanket ic programme development, electro-thermal blanket programme development。