Product picture


Product characteristics
1. Small size, light weight, easy to install and fast
2. Auto-run and manual de-wetting switch, temperature start value and de-wet start value adjustable
3. A comprehensive treatment of the closed electrical cabinets against humid dehumidification has been achieved effectively through the active condensation of the dehumid windway and the heating and wetting of the discharged gas
4. 24-hour real-time sampling of humidity, temperature sensors exceeding the default start value for automatic condensation
5. Humidity, temperature setup has memory functions and does not disappear as a result of the shutdown
6. The malfunctioning function, which allows for quick identification of the failure points to ensure proper functioning
7. The introduction of specialized flood protection components to ensure normal work in a humid environment
The application of shielding techniques, meeting the level 3 standard of gb/t17626-2008, to ensure that they are capable of working in a strong electromagnetic field
Product functions
Low-temperature heating control function: when the temperature of the container is below the set start value, the internal temperature control circuit is activated (with power ranging from 50 to 300 w in addition to the heating unit) until the temperature of the container rises to the set start value plus 5°c. [control of circuit output: non-existent]
High-temperature start windmill control: when the temperature of the container is above the set start value, the internal temperature control loop (with a power range of 50 to 300 w) is activated except for the wet unit, until the temperature of the box drops to a set start value of 5°c. [control of circuit output: non-existent]
3. Fault output: when the smart cabinet dehumidifier fails (the main failures include temperature, humidity sensor failure, wind engine failure, chiller failure), the passive interface is closed。
4. The passive point output can be set as the dewetting indicator function: this point is closed when the dehumidifier is activated; it is disconnected when the dehumidifier ceases to dewet. [output mode: no source]
Rs485 communication function: when data from the uploading machine are received by a de-wetting device with rs485 communication function (communication light flashes) then the data is returned to the uploading machine as soon as the data is analysed. [reduced device rs485 communication supports two communication protocols: company customisation agreement and modebus-rtu agreement]