Westgate controller rwd60 westgate controller rwd60
Description: siemens universal single-range in situ control rwd60 west gate control rwd60 for hvac and refrigeration system comfort control — independent electronic universal controller with p or pi response — working voltage is ac 24 v
Siemens controller, siemens in situ controller, siemens temperature controller, siemens rwd controller, siemens general controller, siemens universal one-language control
Siemens controller rwd60 for hvac and cooling system comfort control
• independent electronic universal controller with p or pi response
• work voltage is ac 24 v
• control applications can be selected by applying numbers
• selection of active input ranges
• the limits and direction of the output range are freely distributed
• 2 generic input terminals to connect ni 1000, pt 1000 temperature sensors and dc 010 v signals
• could set units at °c, °f, %, or not specify units
• 1 dc 0. 10 v regulate signal output, positive or negative
• all data can be entered or changed without the need for other tools using the operational buttons on the controller
Westgate controller rwd60
Siemens controller rwd60 is intended for hac and refrigeration systems in comfort control equipment. The controller may be installed in the control cabinet, or in the windpipe, on the wall and in the machine room, with the help of the arg62. 21/arg62. 22 shell。
The siemens controller rwd60 is a simplified version of the dual-output rwd62 controller that includes all the features and functions of the rwd62 controller but is more competitive. The siemens controller rwd60 is oriented towards a vast one-way, single-out market。
Overview of siemens controller rwd60 functionality
• siemens controller rwd60
Independent controller with 1 dc 0. 10 v output root for positive or inverse uses. Adjustable parameters, including scale bands and points operating time。
• optional auxiliary functions
General inputend x2:
-pi limitr function (absolute and relative)
- remote setting function
- serial control function
- compensation for assigned value
- winter/summer mode
- top priority
Input output point
Input common points: 2; numerical points: 0
Output simulation: 1; numerical point: 0
Westgate controller, rwd60
G, g0 ac 24 v power
M local end g0, for digital input, generic input and simulation output
X1 signal input (main input ls ni 1000, pt 1000 and dc0. 10 v)
X2 signal input (auxiliary input ls ni1000, pt1000, dc010v and 0... 10000 times or dc010v set values remotely)
Y1 simulation output