The stainless steel discharge pump is selected, and the alkalinity of water quality, etc., is identified, and the appropriate stainless steel is selected. General 304 materials fit between ph4 and 10, beyond which 316 or 316 l stainless steel is recommended. Smart high power sewage shredding pump (two pump smart) product no. 206/207 welcomes the use of upgraded products, with a hand summary: toilets, showers, kitchens or basement sewage for use in toilets without sewage pipes are released to high places. A smart double-pump system for multi-equipment access such as a toilet + a wash table + a shower room requires long periods of high power emission users. The main sub-pump works alternately, and when the main pump does not reach the discharge or accidentally ceases to work, the sub-pump is activated and alerts users to let the pump rest or maintain the pump. It can raise sewage by more than 6 metres and release 50 metres. Far
Technical parameters:
The new type of pumps developed by the company are the type 7 fully automated smart double-pump sewage lifters, which focus on: (1) the need for multiple user equipment access that requires large loads and long discharges of sewage. In the case of increased shower water, kitchen water, etc., the main sub-pump alternately works; (2) when the main pump fails to discharge or unexpectedly stops, the sub-pump works and the use is safe; (3) an additional sound alarm system for accidental spills of sewage has been introduced to alert users to allow the pump to rest or to maintain in a timely manner to prevent spills; (4) when the pump is maintained, the main pump fails to clean the pump tank and improve the maintenance of the maintenance environment. The upgrading system addressed: (1) the replacement of the old rubber membrane control system with a sewage non-exposure air control system; (2) the addition of an additional sewage spill warning system and the forced release of sewage from the sub-pumps (which was not a function of other pumps); and (3) the problem of vacuums in the current market of reflows of sewage from the electric toilet system that may not be drained. (six series of double pumps) quantification speed: 2850r/m 4. Quantification flow: 2m3/h 5. Single emissions: ≤2. 5m3/second 6. Level emission distance: ≥ 50m vertical emissions:
Description of use:
Upon receipt of the pump box, the user in the province should open the pump box to remove the seismic object which was deliberately blocked by the transport plant, and check whether the pump and the pipe connection is abnormal; type 2. 71 and type 72 pumps, without additional revolving valves, should be purchased by the plant to stop access valves; 3. Initial use, with first-use powering followed by discharge of the stainless steel pump supply having to be reliably connected; 4. Press the red button to the left of the moving box to test whether the pump is functioning properly. At the same time, water leaks from the pipes, pumps and tanks are observed and disposed of in a timely manner; 5. The pump should be open for a certain period of time, so as to remove in a timely manner the alien from the case that is not broken and prevent the alien from entering the pump from being stuck or entangled; 7. It is prohibited to enter unbreakable objects, plastic paper, sanitary towels and other objects that are not easily shredded; 8. 72 pumps are added to the sewage spill alert system, and when the main pump is stopped for unknown reasons, the pump will be delivered in a timely manner to avoid the main pump start-up process (sequent) and to prevent the spilling of sewage while sounding