    Key Point:If your air conditioner is a hale 5p air conditioner, you can find mr. Electric beijing's electrical maintenance company to help you find and maintain the malfunctions. A simple method of eliminating the failures is presented below。Mr. Electric first came to get a malfunctioned air conditioner for your analysis: when a heil kfr-120/lw/l air conditioner was cooled, everything was normal when it was running, it was automatically shut down af

    If your air conditioner is a hale 5p air conditioner, you can find mr. Electric beijing's electrical maintenance company to help you find and maintain the malfunctions. A simple method of eliminating the failures is presented below。

    Mr. Electric first came to get a malfunctioned air conditioner for your analysis: when a heil kfr-120/lw/l air conditioner was cooled, everything was normal when it was running, it was automatically shut down after 10 minutes, and the running and timing lights were out, the power lights were blinking, flashing six times, suspending one time, so sawring. The power supply to the air conditioners was cut off for five minutes and restarted, and was able to work properly, but again after 10 minutes。

    On the basis of the above-mentioned malfunction, the failure should be "indoor temperature sensor short circuits or road failure" as suggested by the hale cabinet series air conditioner failure code. According to this instruction, the first replacement of the indoor temperature sensor and the recurrence of a failure after minutes of normal operation of the testi on the engine may be judged to be not caused by an interior temperature sensor failure. The most likely cause is the anomaly of the metre on the main panel of the indoor temperature sensor in the air conditioner. However, test malfunctions continued to occur after replacement of the interior master panel。

    Hale commercial air conditioning maintenance manual

    Once again, the failure of air conditioners was carefully analysed and studied, and it was concluded that the cause of the failure could be caused by anomalies in a component of the air conditioner operation. The outdoors of the air conditioners were then inspected, and it was found that the cooling fans were slow to function while working; after the shutdown, the temperature of the units was significantly higher. The reasons for the slow operation of the phoenix electric power plant may be due to insufficient start-up capacity, resulting in a low start-up rectangular power of the mouse fan or short circuits between the circuits. Check the start-up capacitor with a rated value of 10 μf, which was measured at 2. 8 μf, well below the rated value. The replacement of the capacitor was restarted, the air conditioner was normal and the failure was not repeated, which confirmed that the failure of the air conditioner was due to the insufficient capacity of the fan generator to start the capacity。

    As can be seen from mr. Electric's introduction of the failure removal process for the air conditioner, the source of the failure of the power signal that led to the type of air conditioner is not just one of the reasons suggested in the failure code, and the failure of the air conditioner condenser in the outdoor air conditioner can also cause the power signal to blink。

    Having seen mr. Electric's presentation of the solution to the problem of the flash failure of the hal ac light, although we can remove it at home and find the root cause, since the vast majority of users are not familiar with some mechanical ac in-house knowledge, from the point of view of the long-term use of domestic electricity and personal safety, you should find a beijing electric maintenance company to help you solve this problem

     