Fire-fighting equipment and maintenance systems fire-fighting equipment 1. All fire escape signs in the building shall remain in good condition and shall remain in normal working condition after power has been out. All fire-fighting equipment in the building shall be tested monthly and repairs and records shall be made as soon as malfunctions are detected. Any firefighting equipment installed in the aircraft room shall be inspected once a week. 4. Fire alarms should be tested monthly and should be repaired and recorded immediately in case of failure. 5. The fire pumps shall remain in good condition, the valves shall not be accidentally closed and the water level of the fire tank shall be normal. 6. Fire maintenance certificate. 7. Fire drills should be conducted annually. The fire system/equipment maintenance system automatically fire alarm hosts and smoke/temperature detectors are generally external maintenance, property management companies are required to maintain records and regular inspections, tests and maintenance repairs are required for various fire alarm devices. 1. Fire alarm controllers shall be inspected on a daily basis and as required
The format (schedule i, schedule ii) completes the system operation and controller daily check registration form and detects failure to clear it in a timely manner. 2. The following features of the fire protection system/equipment shall be inspected and tested on a quarterly basis and the quarterly registration form shall be completed (schedule iii). 2. 1 the actions of the test detectors and the identification of light displays using special detection instruments in series. 2. 2 acoustic light display of the test fire alarm device. 2. 3 test current indicator, pressure switches, alarm function, signal display, etc. 2. 4 conduct of one to two recharge tests of the back-up power source and one to three automatic switching tests of the main and back-up power source. 2. 5 the following fire-fighting equipment is automatically or manually inspected: 2. 5. 1 anti-smoke equipment (which can be inspected twice a year), electric fire valves, electric fire doors, fire curtains, etc. 2. 5. 2 indoor flammation, automatic water spraying and fire suppression systems. 2. 5. 3 water spray fire suppression system. 2. 5. 4 fire incidents broadcast, fire incidents

3. Lights and evacuation signs. 2. 6 forced fire elevators to stop at the front floor test. 2. 7 the fire communications equipment shall be subjected to a radio conversation test in the fire control room. 2. 8 check all conversion switches. 2. 9 compulsory disconnection of non-fire-fighting power function tests. 2. 10 activate fire pumps, spray pumps, and check sound, vibration, current, voltage and pressure. 3. The operation of fire-incident broadcasting equipment is tested once a year, and all fire extinguishers are thoroughly inspected once a year, and the replacement or suppression of liquids is done according to different types. 4. After two years of operation, the detector shall be thoroughly cleaned every three years, and the response threshold and other necessary functional tests shall be performed for continued use by the qualified, and re-installation shall be strictly prohibited for those who do not. The day-to-day fire inspection process is handled by sub-contracting units accredited by the fire department for fire equipment maintenance, and by the ministry of works and the department of security for the operation of fire control
4. System operations, in the event of a malfunction on the system, engineering and security personnel are required to understand the cause of the failure and to reposition the system, to keep the fire system in normal condition for 24 hours, and to record the location and failure of the failure point, to notify the maintenance sub-contracting unit and to perform repairs. In the event of non-reversible failure of the fire protection system, engineering personnel should stop the alarm bells in real time, and the central air-conditioning refrigeration and ventilation system, so as not to affect the building users, and immediately notify those responsible for the maintenance of the sub-contracting unit, for emergency inspection and maintenance. After notification of the sub-contract, the ministry of works or the security service shall record the time of the failure, the reason, the time of the sub-contract, the name of the sub-contract processor, the time of the sub-contracting to the building, the name of the maintenance officer, the time of completion of maintenance, the cause of the failure, the method of repair, the replacement of the name and number of spare parts, etc., and, upon completion of the report, submit the statement to the manager of the ministry of works,

5 for use as a subcontract for accounting maintenance. 24-hour failure of the fire control and security personnel to verify the cause of the system failure and silence the monthly maintenance inspection notified the engineering manager or chief engineer of the subcontract to perform emergency maintenance suspension alerts and to complete temporary emergency repairs for the re-entry of the attached air conditioner (e. G. Explosive fire showers)
6. Period and time: () subcontract completion time: (a) subcontract treatment method: signature by the head of subcontract: date: signed by the head of engineering/security department: date: : date: note: routine inspection log building for fire pumps: system and equipment: location: date of record: water storage tank condition/capacity/existing water pressure tank condition/capacity/existing water entry/exit valve operation to control the condition of the water pressure valve operation (a)/voltage (v) water pump core: normal positioning of the flow valve operation and other: other: condition of the emergency shut-down mechanism for running water pipelines of the water tank equipment/capacity/existing water pressure tank/capacity/existing water valve operation for access to and access to the water pressure valve operating conditions of the water control valve: other: condition of the discharge/barrelation valve operation of the drainage system

7 other: note: record: audit: six-monthly maintenance log number for fire pumps: system name: spray head pump 001 system number: fs-sp-b-001: maintenance project maintenance and treatment maintenance unit confirm that the examination plate check plate for lubricating oil follows the cable line close to the ground during the year, secures the outside view of the main contact point checker for the acoustic pump shell open, long-barrier-free and fully connected, smoothing of the valves to the valve, instructs the three-phased electric power machine to conduct an automatic check of the electric insulation a, b, c (c), c (c) and c) automatic pump check
• date of the performance of the fire control screen for the operation of the fire control screen for damage to the smoke/heat control screen