    Key Point:As technology evolves, the type of household electricity becomes more abundant and, as far as air conditioning is concerned, the array, wall, frequency, intelligence, etc. Are fully functional。However, after a long period of use, air conditioners have suffered minor malfunctions, and today they share common failures and maintenance methods。Methodology/step1. Compressor inoperableReason for failure: power failureMethod of exclusion:

    As technology evolves, the type of household electricity becomes more abundant and, as far as air conditioning is concerned, the array, wall, frequency, intelligence, etc. Are fully functional。

    However, after a long period of use, air conditioners have suffered minor malfunctions, and today they share common failures and maintenance methods。

    Download of technical information on air conditioning maintenance

    Methodology/step

    1. Compressor inoperable

    Reason for failure: power failure

    Method of exclusion: dismantling of malfunctions by universal-use watch and electronic pen. The fuse is broken, the fuse is replaced, and the wire is broken。

    Reason for failure: power pressure is too low

    Method of exclusion: measurement of voltage values on a single scale and, if necessary, power-pressure devices。

    Causes of failure 3: loose or broken wire connections

    Method of exclusion: inspection of wire connections, re-insulation of loose plugs, tightening of plugs, professional overhaul。

    Download of technical information on air conditioning maintenance

    Wind machines are not operational

    Reason for failure: poor contact with the main switch

    Method of exclusion: the main switch contact point electrical resistance is measured on a universal scale and should be repaired or replaced when the resistance is too large or zero。

    Fault cause 2: fan wire damage

    Method of exclusion: replacement of fans with the same specifications and the same speed with a universal watch。

    Causes of failure 3: loose bolts between wind engine electrics and wind leaves

    Method of exclusion: tightened screws。

    Causes of failure 4: break-down or short of fan capacitors road

    Method of exclusion: inspection of capacitors and replacement of capacitors of the same specifications。

    Download of technical information on air conditioning maintenance

    3. Compressor start and stop frequency

    Reason for failure: inappropriate room temperature control

    Method of exclusion: increase, as appropriate, the margin between indoor control temperature and primary temperature。

    Reason for failure: over-temperature

    Method of exclusion: improvement of the working environment, such as the installation of a fence, avoidance of sunlight, installation of air conditioners in a well-ventilated environment, etc。

    Reason for failure 3: condensers are dirty

    Method of exclusion: clean the condenser and remove the dust from the outer surface of the condenser。

    Download of technical information on air conditioning maintenance

    4. Non-regulated heat-refrigeration function of hac

    Reason for failure: electromagnetic switch to valve loop failure

    Method of exclusion: the electro-magnetic membrane measure is used to convert to the valve wire, and if it is broken or burned, a new electro-magnetic valve of the same size should be replaced。

    Reason for failure: failure of electrical heating unit

    Method of exclusion: replacement of electro-heated silk or temperature protections of the same specifications with a universal watch check。

    Causes of malfunction 3: temperature controller failure

    Method of exclusion: the temperature controller of the same specification shall be replaced with a universal meter to check the thermostat, and if it is still ineffective after de-stereolysis of the contact point。

    5. Leakage

    Reason for failure: the horizontal tilt angle of window air conditioner installation is insufficient

    Exclusion method: window air conditioners are re-installed in the correct manner。

    Reason for failure: drain blockage

    Method of exclusion: clean-up of congestion。

    Reason for malfunction 3: inadequate level of interior installation

    Method of exclusion: re-equipment of indoor aircraft using a horizontal device。