As people's standard of living continues to improve, air conditioning has become a household requirement, and the addition of air conditioners has contributed to the beauty of our lives, but in the cold winter, when air conditioners are not hot, there is no love in life. Now, let me tell you a little bit about how new air conditioners can be dealt with。

Apply a universal watch first to check the wiring of the electromagnetic ioniser for guidance, if possible, and then to remove high and low pressure to cut the power plugs of the switch, and first to check the pressure switches and see if the two sets of high and low pressure contact points are connected. If capable of doing so, re-measure the availability of electricity at power plugs. Finally, the system's power source is checked for voltage, reliability of exposure, etc. The failure of the compressor, through a circuit check, is generally resolved。

Refrigerants are key to the operation of air-conditioning, and air-conditioning cannot function without them, so the leakage of air-conditioning refrigerants is one of the most painful problems faced by some consumers in the use of air-conditioning, judging the air-conditioning state from the temperature of each ministry, touching the air-conditioning system and components by hand, checking surface temperature and, normally, the low temperature of low-pressure pipe roads, the high temperature of high-pressure pipe roads, and cleaning up of miscellaneous items on air-conditioning units. Check the evaporation route and the condenser surface, as well as the presence of impurities and sludge between the condenser and the engine water tank (stop-check), be careful to clean, clean carefully, and the condenser can wash lightly with a brush and be careful not to wash with steam。
Wind turns are slow, wind speeds are measured using wind speed regulation (high, medium and low), wind speeds are not clearly shown to change, wind is checked, the face of the wind is good, the main plate control wind relays have a visible acoustic sound, thus removing electrical failure, problems may be caused by a evaporation block, the amount of wind remains unchanged after cleaning the internal evaporation unit, the internal windways are not blocked, wind changes are determined to be small in other normal cases when the windways are not clear, and the internal panel is removed to lift up the steamer before a careful examination of the fumigator has been conducted。

For the time being, these methods have been made available and, in general, the problem of non-heated new air conditioners has been resolved, in the hope that in the cold winter, you will be relieved. The new air conditioner is not hot, but it is not a very big problem, and everything can be solved with a mastery of methods。