Share EncyclopediaHome EncyclopediaCategories Switch Channel

Vishay celtron's single-point retweeting. Device

2026-04-13 09:171270NameNetworking

The guangzhou electronic technology introduction to the vishay celtron single-point heavy sensor applies to industrial or commercial weighing applications of medium range (200kg). The following are its key performance characteristics and selected recommendations:

Hydraulic-style heavy sensor construction

Core performance characteristics

1. Measurement and precision

Scaled capacity: 200kg

Consolidated precision: usually 0. 02% fs (full range) or higher, depending on the model suffix (e. G. Lps 200kg c3)。

Non-linear, delayed: 0. 02% fs (typical value)。

2. Structure design

Single-point structure: suitable for applications such as platform scales, scales, etc., insensitive to load positions, easy to install。

Materials: alloy steel or stainless steel (optional corrosion resistant type), protection level ip65/ip67 (dustproof protection)。

Electrical properties

Output sensitivity: 2 mv/v (standard), with incentive voltage (usually 5,12 vdc)。

Incentive voltage: 10vdc (maximum 15vdc)。

Temperature compensation range: 10°c ~ + 40°c (a wide temperature model of up to 30°c ~ + 70°c)。

4. Mechanical parameters

Safe overload: 150% fs, limit overload: 300% fs。

Worms: ±0. 02% fs/30min (typical)。

5. Certification and compliance

Compliance with measures such as oiml r60, ntep (specific models to be identified)。

Strength and fit scenario

Strengths:

High stability and repetitiveness, low long-term use of drift。

Whispering brands are highly reliable and resistant to interference (emc performance)。

For dynamic or static weighing (e. G., weighting of production lines, storage logistics)。

Typical application:

Industrial scales, packaging scales, sorting equipment。

Medical equipment, food processing (requires stainless steel models)。

Selective care

1. Model suffix:

Identification of specific models (e. G. Lps 200kg c3 or lps 200kg s) with different suffixes that may vary between output lines (4 lines/6), contact types or protection levels。

2. Supporting instruments:

Matches a reset or monitor (e. G., the ind570 series of vishay) that supports 2 mv/v input。

3. Environmental adaptation:

Corrosive environment select stainless steel (e. G. Lps 200kg ss)。

Isp67 protection is required in high humidity settings。

4. Installation requirements:

Ensure that the base level is flat and that the side forces do not affect accuracy。

Like 0
Report
Favorite 0
Tip 0
Comment 0
Share 8
MoreRelated Comments
No comments yet, be the first to comment
Old things make dreams. They write love letters for their childhood with junk
Did you ever do that when you were a kid -- you saved a drawer of popsicle sticks to build a small house? The power of the stock, "snatching for the world", has been hidden in the hearts of many。In henan, there's an old man named dachang, who's trying to make it real. Over the past 15 years, nearly 30,000 strangled cans, without entering the recycling site, have become his family's private convoyland cruisers, helicopters, even tanks. Neig