This is followed by the introduction of solid electromeasures, which are combined by solid electron thermal wire, ceramic dishes (fire-resistant bricks), metal casings and thermostats to achieve continuous heating, which are internalized with asbestos as a heat-storage energy structure for insulation protection, meeting the requirements for gradual release of heat, with automatic overheating protections, and electrical instruction devices. The popular term solid electrode is a small electric furnace controlled by a ptc heat-sensitive electrical switch, which heats itself when the electricity flows out of time and the heat of the furnaces is passed on to it. When its temperature reaches a certain limit, its electrical resistance values rise dramatically and become infinite until the power is cut. At this point, the power can be removed and the heat from the internal resistance wire and the remaining temperature of the ceramic plate will slowly be heated out through asbestos and internal hot air。

When such products appear unheated, they are generally poorly exposed to power lines, which can be directly addressed by replacing new ones. If there is internal damage, it can be removed for overhaul, but since the frame around it is welded, it is difficult for ordinary users to fix it。

The perimeters around the scavengers are removed with sharp-mouth pliers and a small one-word screw, so that internal ceramic plates, electrical resistance wires, asbestos, thermostats, racks, wires, etc. Can be seen. When unheated currents appear, the barrier to electrical resistance can be measured using a single-use watch, typically at a maximum of a few dozen om, which needs to be replaced if infinity of the barrier is to be found. The replacement can be replaced by the purchase of a brand-new electrical barrier or by the replacement of old wires, entangled in the original position, wired to the end of the connection, and the screws must be sharpened or burned by a false fire. If electrical resistance is found to be good, but without electricity, then the two feet of the thermostat (with two thermostats, one ptc component and the other an ordinary jump temperature control) can be measured, and in the absence of electrostatic heating, in the case of ptc elements, the barrier is around a dozen om, and in the case of a jumper, there is no resistance equivalent to a guidance line. If an abnormal and timely replacement of phase fittings is found in the survey, all the thrusts are screwdrivers for easy dismantling。

The damage was caused by the failure of the main end of the connection to set fire to the electrical barriers and to remove them from service. When wired, internal asbestos is returned to its original position with a light pressure of tweezer, and during maintenance, no asbestos should be placed on the body, which would otherwise be intriguing. When the internal asbestos is fixed, the lid is covered, and the lid is installed with some effort, since the internal asbestos is more resilient, so it is best for two people to work together, one with the lid and one with the outer frame. When this is done, weld the border with a small welder and then weld the border。