It would have been a few more years before retirement, and it would have been easy to lay down, just to have to go to class, but it was often seen that the room manager had to come and go back and forth to protect the software several rounds before the computer was restored and removed from protection, then to transfer it to the entire room with the same message and sometimes to fail. Poor baby! For example, a high-school it test software, a simulation exercise, a simulation of the exam, at least a three-time test, exhausting teachers and administrators
Later on, i couldn't stop thinking about the server that used to be in the old campus, and now i've moved to the new campus, and i found the logistics to ask where the server was. It's in the basement warehouse. I went to look for it, look at it in the corner, it's full of dust, and i'll use it as a cloud desktop server, and then i'll use it as an undisclosed workstation to connect the server, install the system, install a workstation, post the desktop, all the same, how all the student machines damage the computer, just restart it and go back to the original installation of the system, install the polar-level student-end software at the workstation, install a slightly better teacher-end software on the teacher machine, thereby significantly reducing the workload of the room manager and the teacher

Based on the above, i cleaned the server and saw that it was purchased by wah for rh2288 v3, 2017. However, once the server power was pressed, it could not be turned on! Turn on the hood and see no apparent anomalies on the main plate. Because it's normal not to start in a warehouse as if it's garbage, cpu is the strongest e5-2609v3, judging by the main panel, which is the mechanical hard drive of the sas interface of 2. 5 inches and 300 g, with a memory of only 8g, a configuration that is not good enough to drive 60 workstations。
Considering that more workstations may be connected in the future, the following accessories were found on the internet: an old master plate, 4 32gb memory, 3 800g solid-state hard drives (two of which are raid1 installed systems), 1 terabytes card, 1 terabytes switch, and 1 to powerful e2650/cpu。
After the purchase was returned, a process was also initiated to rewrite the above hardware, and two solid hard drives were rad1 and the installation of windows servicer 2008 began through ibmc. Following the successful installation of the system, the installation of cloud desktop software, the selection of a rdv cloud desktop software, the installation of a service-end application on the server, the selection of a workstation as a template, the installation of an operating system on a disk, and the installation of a client software at a given time were initiated, followed by the deployment as described in the software, especially since the service-end installation gateway was 192. 168. 212. 254, after the start of the workstation became 110. X. X. As a result, workstations were not available on the internet, and manual modifications were needed to understand it. The reason for the subsequent screening was that the school local area network had a dhcp server and that the entire campus network was accessible. The problem was solved by fine-tuning the network segment。
As a result, the system in room 201 has been operational for some time after its deployment. Then it suddenly came to mind whether the old machines in the 202 rooms could be connected together, but to divide them into another section of the network, 192. 168. 213, which would allow the teachers in the two rooms to control each other without affecting each other, would also facilitate centralized management。
However, the old machines are too old to be associated with the acquisition of m4360, which was acquired in 2015 with only 4m in memory, and some of the original m4350, which is in use. It's a waste of time to install software. So, my old man's passion came up, first with an m4350 template machine with a win7-64 flagship version, but whether the hard drive is in the mbr or the guid subsectors, corresponding to the legacy and uefi start, the system configuration is completed and it can't be activated by pxe. It was later replaced with the installation of the win10,64 bits, which could be connected, but could only be activated in the usual user mode, not in the configuration system (supplier)! And the win10 was stuck on the old machine. It's been too long! Next thing you know, if you don't have a win 7-32, it's going to go for legacy. So let's go。
Please leave a message
#rh2288 #no disk # cloud desktop